Section 753 has been revised and now deals with all embedded electrical systems for surface heating.
![17th edition wiring regulations bs7671 17th edition wiring regulations bs7671](https://i.ebayimg.com/images/g/h8wAAOSwx2FbzIqq/s-l64.jpg)
A particular requirement for B-type RCDs in charging points and a repeal of exemptions for PME supplies are important and may require updated equipment. Of particular note to test and measurement, there will be new requirements for electrical installations in caravan/camping facilities (Section 708) installations in caravans and motor caravans (Section 721) and electric vehicle charging points (Section 722). Various specialist installations have been introduced into the scope of BS7671 whilst the regulations surrounding others have been modified. This will expand the scope where protection is required, except in certain single dwelling units, and once again these additional systems will need to be thoroughly tested. Where the need for protection against transient overvoltage used to be defined by the AQ criteria - effectively considering the frequency and likelihood of lightning strikes - these have now been replaced by criteria considering the potential consequences of lightning strikes. One of the most significant changes in the 18th edition is the overhaul of Section 443 which deals with overvoltage caused by atmospheric conditions, i.e. The latter section refers to protective conductors in installations supplied by multiple power sources. Newly introduced regulations 542.2.3 and 542.2.8 define new requirements for earth electrodes whilst two further regulations (543.3.3.101 & 543.3.3.102) cover the installation of switching devices in protective conductors.
![17th edition wiring regulations bs7671 17th edition wiring regulations bs7671](https://i.ytimg.com/vi/c4BsettT0N8/maxresdefault.jpg)
There are several changes to earthing systems contained within the 18th Edition. Further changes have been made in chapter 56 which deals with protection, isolation, switching, control and monitoring. It also deals with switching used to control circuits and equipment although any circuits or equipment that come under BS EN 60204 are solely covered by that standard. The new Chapter 46 of the 18th Edition Wiring Regulations discusses non-automatic local and remote isolation and switching when these measures are used to prevent or remove dangers associated with electrical installations and equipment. It is also important to note that Table 41.1 now applies to final circuits rated up to 63A (with sockets attached) so maximum disconnection times will apply to a greater number of circuits, thus requiring accurate testing with appropriate equipment. In particular, <30mA RCDs will now be a requirement on sockets rated up to 32A (unless deemed unnecessary by a risk assessment) rather than just 20A (411.3.3), whilst they will also be needed on all AC final circuits supplying luminaires within residential buildings (411.3.4). The 18th Edition is characterised by increased prevalence of protective RCDs in a range of installations so there will be greater need for RCD testers and MFTs with a reliable RCD testing function. It is set to supersede the previous 17th edition on 1st January 2019 and contains multiple changes, although not all of these are pertinent to test and measurement. The 18th Edition of the BS7671 Wiring Regulations has been finalised by the IET and will be issued on 2nd July 2018.